Difference between revisions of "TUFLOW Message 2074"
Jump to navigation
Jump to search
(5 intermediate revisions by 3 users not shown) | |||
Line 3: | Line 3: | ||
|alt_msg=NA | |alt_msg=NA | ||
|type=[[WARNING]] | |type=[[WARNING]] | ||
− | |message_desc=SA object does not select any 2D cells (active or inactive). For example this could occur when 2d_sa object is outside the active model area. | + | |message_desc=SA object does not select any 2D cells (active or inactive). For example this could occur when a 2d_sa object is located outside of the active model area. This warning may also occur if the digitised SA polygon does not select any cell centres (ZC points), in the figure below the polygon highlighted in pink does not contain any cell centres and therefore this warning message will be returned.<br> |
− | |suggestions=Check SA object and ensure that it is an active model area or chose a different inflow location. | + | [[File:WARNING 2074.jpg|600px]] |
− | + | |suggestions=Check SA object and ensure that it is an active model area and selects at least one ZC zpt, or chose a different inflow location. | |
− | + | ||
− | + | ||
− | |||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 11:57, 23 December 2022
TUFLOW Message
WARNING 2074 - SA object does not select any 2D cells (active or inactive).
Alternate Message
NA
Message Type
WARNING
Description
SA object does not select any 2D cells (active or inactive). For example this could occur when a 2d_sa object is located outside of the active model area. This warning may also occur if the digitised SA polygon does not select any cell centres (ZC points), in the figure below the polygon highlighted in pink does not contain any cell centres and therefore this warning message will be returned.
Suggestions
Check SA object and ensure that it is an active model area and selects at least one ZC zpt, or chose a different inflow location.