Difference between revisions of "TUFLOW Message 2051"
Jump to navigation
Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=???? |message_desc=Connection object unused or not snapped to a 2D HX or 2D SX object. All connections (CN objects) must be snapped to a 1D/2D i...') |
|||
(4 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{TUFLOW_Message | {{TUFLOW_Message | ||
− | |tuflow_message= | + | |tuflow_message=ERROR 2051 - Connection object unused or not snapped to a 2D HX or 2D SX object. |
+ | |alt_msg=WARNING 2051 - Connection object unused or not snapped to a 2D HX or 2D SX object. | ||
+ | |type=[[ERROR]] <br> [[WARNING]] | ||
|message_desc=Connection object unused or not snapped to a 2D HX or 2D SX object. All connections (CN objects) must be snapped to a 1D/2D interface object. | |message_desc=Connection object unused or not snapped to a 2D HX or 2D SX object. All connections (CN objects) must be snapped to a 1D/2D interface object. | ||
− | |suggestions= | + | |suggestions=Review boundary configuration, if a HX or SX boundary is desired ensure HX or SX object exists and CN object is correctly snapped. If no boundary is desired remove CN object. |
− | + | ||
− | + | ||
− | + | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |
− | |||
− | | | ||
}} | }} |
Latest revision as of 11:40, 23 December 2022
TUFLOW Message
ERROR 2051 - Connection object unused or not snapped to a 2D HX or 2D SX object.
Alternate Message
WARNING 2051 - Connection object unused or not snapped to a 2D HX or 2D SX object.
Description
Connection object unused or not snapped to a 2D HX or 2D SX object. All connections (CN objects) must be snapped to a 1D/2D interface object.
Suggestions
Review boundary configuration, if a HX or SX boundary is desired ensure HX or SX object exists and CN object is correctly snapped. If no boundary is desired remove CN object.