TUFLOW Message 2215: Difference between revisions

Content deleted Content added
No edit summary
No edit summary
 
(3 intermediate revisions by 2 users not shown)
Line 3:
|alt_msg=NA
|type=[[WARNING]]
|message_desc=A 1D pit object can be connected to a maximum of wjs???10 2D cells.
|suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer. If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit.
 
|discussion_page=* [[Talk:TUFLOW Message 2215|Discuss Message 2215]]
If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. To use this approach, the 1d_nwk "Q" pit will need to be set up as a line rather than a point.
|link3=''
 
|link4=''
|prelink=[[TUFLOW_Message_2214|Message 2214]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2216|Message 2216]]
}}