TUFLOW Message 2060: Difference between revisions

Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=???? |message_desc=Unrecognisable .tbc file command or an error reading data for a boundary condition in the old fixed field format. If it canno...'
 
No edit summary
 
(12 intermediate revisions by 4 users not shown)
Line 1:
{{TUFLOW_Message
|tuflow_message=ERROR 2060 - Unrecognisable .tbc command or problem reading BC data in fixed field format.<br>
|tuflow_message=????
Incorrect Line = "xxxxxx"
|message_desc=Unrecognisable .tbc file command or an error reading data for a boundary condition in the old fixed field format. If it cannot be resolved contact support@tuflow.com.
|alt_msg=NA
|suggestions=????
|type=[[ERROR]]
|discussion_page=* [[Talk:TUFLOW Message 2060|Discuss Message 2060]]
|message_desc=.tbc command is invalid or BC input file (e.g. bd_dbase.csv, HT/QT table, and etc) isn't in the correct data format.
|link3=''
|suggestions=Check which line in the input file is causing the issue from the error message, and ensure that .tbc command has no misspelling, or the input data is in the correct format.
|link4=''
 
|prelink=[[TUFLOW_Message_2059|Message 2059]]
 
|nextlink=[[TUFLOW_Message_2061|Message 2061]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
}}