− | |tuflow_message= | + | |tuflow_message=ERROR 2062 - SC connection cannot connect to a HX line. |
+ | |alt_msg=NA | ||
+ | |type=[[ERROR]] | ||
|message_desc=Source conection (SC) cannot snap to a 1D/2D interface (HX) line. Source connections can only be connected to a Source versus Water Level (SH) boundary object. | |message_desc=Source conection (SC) cannot snap to a 1D/2D interface (HX) line. Source connections can only be connected to a Source versus Water Level (SH) boundary object. | ||
− | |suggestions= | + | |suggestions=SC line should only be used with SH boundary object. For SX and HX connections use CN objects. |
− | + | ||
− | + | ||
− | + | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |
− | |||
− | | | ||
}} | }} |
Latest revision as of 11:54, 23 December 2022
TUFLOW Message
ERROR 2062 - SC connection cannot connect to a HX line.
Alternate Message
NA
Message Type
ERROR
Description
Source conection (SC) cannot snap to a 1D/2D interface (HX) line. Source connections can only be connected to a Source versus Water Level (SH) boundary object.
Suggestions
SC line should only be used with SH boundary object. For SX and HX connections use CN objects.