TUFLOW Message 2063: Difference between revisions
Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=???? |message_desc=Single connection (CN) to 1D Node must have a weighting factor (f attribute in 2d_bc layer) of one (1.0). As of Build 2004-07...' |
No edit summary |
||
| (3 intermediate revisions by 2 users not shown) | |||
Line 1:
{{TUFLOW_Message
|tuflow_message=ERROR 2063 - Single CN connection to 1D Node must have a weighting factor (f) of 1.0.
|alt_msg=NA
|type=[[ERROR]]
|message_desc=Single connection (CN) to 1D Node must have a weighting factor (f attribute in 2d_bc layer) of one (1.0). As of Build 2004-07-AC, a zero weighting factor is interpreted as a value of one (1.0).
|suggestions=If using a single CN connection to a 1D node, ensure weighting factor (f) of 1.0 is used.
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
}}
| |||