Difference between revisions of "TUFLOW Message 3011"

From Tuflow
Jump to navigation Jump to search
 
(5 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
|tuflow_message=ERROR 3011: Target control number must be in range 0.001 - 1.2.
+
|tuflow_message=ERROR 3011 - Target control number must be in range 0.001 - 1.2.
 
<br>  
 
<br>  
|alt_msg=None
+
|alt_msg=NA
 +
|type=[[ERROR]]
 +
|message_desc=This error message has been deprecated. If you are still receiving this message with the latest TUFLOW release, please contact [mailto:support@tuflow.com support@tuflow.com].<br>
 +
The Control Number Factor must be in the range 0.001 - 1.2.
 +
|suggestions=Ensure the '<tt><font color="blue">Control Number Factor</font></tt>' TCF command is within the range 0.001 - 1.2. The default value is 1.0.
  
|type=[[ERROR]]
+
Whilst it is possible to increase the default HPC Courant, shallow wave celerity and diffusion control numbers (effectively overclocking the simulation), it is strongly recommended not to increase the Control Number Factor above the default of 1.0. A hard upper limit has been set to prevent an increase of more than 20% (i.e. <tt><font color="blue">Control Number Factor</font><font color="red"> ==</font> 1.2</tt>). Increasing control numbers by more than this would be likely to lead to instability.  
|message_desc=The Control Number Factor must be in the range 0.001 - 1.2.  
 
|suggestions=Ensure the 'Control Number Factor' TCF command is within the range 0.001 - 1.2. The default value is 1.0.
 
  
Whilst it is possible to increase the default HPC Courant, shallow wave celerity and diffusion control numbers (effectively overclocking the simulation), it is strongly recommended not to increase the Control Number Factor above the default of 1.0. A hard upper limit has been set to prevent an increase of more than 20% (i.e. Control Number Factor == 1.2). Increasing control numbers by more than this would be likely to lead to instability.
 
  
|discussion_page=* [[Talk:TUFLOW Message 3011|Discuss Message 3011]]
 
|link3=''
 
|link4=''
 
|prelink=[[TUFLOW_Message_3010|Message 3010]]
 
 
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]]
 
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]]
|nextlink=[[TUFLOW_Message_3012|Message 3012]]
 
 
}}
 
}}

Latest revision as of 13:20, 9 September 2024

TUFLOW Message
ERROR 3011 - Target control number must be in range 0.001 - 1.2.

Alternate Message
NA

Message Type
ERROR

Description
This error message has been deprecated. If you are still receiving this message with the latest TUFLOW release, please contact support@tuflow.com.
The Control Number Factor must be in the range 0.001 - 1.2.

Suggestions
Ensure the 'Control Number Factor' TCF command is within the range 0.001 - 1.2. The default value is 1.0.

Whilst it is possible to increase the default HPC Courant, shallow wave celerity and diffusion control numbers (effectively overclocking the simulation), it is strongly recommended not to increase the Control Number Factor above the default of 1.0. A hard upper limit has been set to prevent an increase of more than 20% (i.e. Control Number Factor == 1.2). Increasing control numbers by more than this would be likely to lead to instability.