Difference between revisions of "TUFLOW Message 3038"
Jump to navigation
Jump to search
Teegan.Burke (talk | contribs) (Created page with "{{TUFLOW_Message |tuflow_message=ERROR 3038: Flow width factors must be >= 0. <br> |alt_msg=None |type=ERROR |message_desc=The value of specified Cell Width Factor must...") |
|||
(2 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{TUFLOW_Message | {{TUFLOW_Message | ||
− | |tuflow_message=ERROR 3038 | + | |tuflow_message=ERROR 3038 - Flow width factors must be >= 0. |
<br> | <br> | ||
− | |alt_msg= | + | |alt_msg=NA<br> |
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc= | + | |message_desc=Faces may have a flow width factor applied to represent reduced available flow area of the face (for example, if a building occupies part of the face).The changed flow width applies at all depths.<br> |
− | + | :For example, a factor of 0.1 will limit the flow width to 10%. <br> | |
+ | When reading from a polygon object in GIS format, any cell sides that fall within the polygon will have the width factor | ||
+ | applied. These factors can be reviewed within the uvpt_check file, and logically cannot be negative. | ||
+ | Negative factors are not permissible. | ||
+ | |||
+ | |suggestions=Review the applied face width factors and ensure none are less than 0. | ||
− | |||
− | |||
− | |||
− | |||
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]] | |uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 10:17, 3 March 2023
TUFLOW Message
ERROR 3038 - Flow width factors must be >= 0.
Alternate Message
NA
Message Type
ERROR
Description
Faces may have a flow width factor applied to represent reduced available flow area of the face (for example, if a building occupies part of the face).The changed flow width applies at all depths.
- For example, a factor of 0.1 will limit the flow width to 10%.
When reading from a polygon object in GIS format, any cell sides that fall within the polygon will have the width factor applied. These factors can be reviewed within the uvpt_check file, and logically cannot be negative. Negative factors are not permissible.
Suggestions
Review the applied face width factors and ensure none are less than 0.
Up |
---|
3xxx Messages |