Difference between revisions of "TUFLOW Message 2441"

From Tuflow
Jump to navigation Jump to search
 
(3 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
 
|tuflow_message=ERROR 2441 -  HQ boundaries not yet supported for GPU Solver.
 
|tuflow_message=ERROR 2441 -  HQ boundaries not yet supported for GPU Solver.
|alt_msg=NA
+
|alt_msg=ERROR 2441 - 2D VG boundaries not yet supported for HPC Solver.
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=The stage-discharge (HQ) boundaries are not yet available in the TUFLOW GPU module.
+
|message_desc=The stage-discharge (HQ) boundaries are not available in earlier TUFLOW GPU versions. The 2D VG boundaries not yet supported for HPC Solver.
|suggestions=The HQ boundary will need to be replaced with a HT boundary. If the water level is at ground level or below, normal flow is applied at the boundary.
+
|suggestions=Use the latest TUFLOW HPC release or the HQ boundary will need to be replaced with a HT boundary. If the water level is at ground level or below, normal flow is applied at the boundary. For functionality of 2D VG boundaries consider using TUFLOW Classic or variable Z shapes in TUFLOW HPC.
|discussion_page=* [[Talk:TUFLOW Message 2441|Discuss Message 2441]]
+
 
|link3=''
+
 
|link4=''
 
|prelink=[[TUFLOW_Message_2440|Message 2440]]
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2442|Message 2442]]
+
 
 
}}
 
}}

Latest revision as of 08:51, 3 March 2023

TUFLOW Message
ERROR 2441 - HQ boundaries not yet supported for GPU Solver.

Alternate Message
ERROR 2441 - 2D VG boundaries not yet supported for HPC Solver.

Message Type
ERROR

Description
The stage-discharge (HQ) boundaries are not available in earlier TUFLOW GPU versions. The 2D VG boundaries not yet supported for HPC Solver.

Suggestions
Use the latest TUFLOW HPC release or the HQ boundary will need to be replaced with a HT boundary. If the water level is at ground level or below, normal flow is applied at the boundary. For functionality of 2D VG boundaries consider using TUFLOW Classic or variable Z shapes in TUFLOW HPC.


Up
Go-up.png 2xxx Messages