TUFLOW Message 1214: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
Created page with "{{TUFLOW_Message |tuflow_message=ERROR 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes. |alt_msg=NA |type=ERROR |message_desc=From 2017 onwards t..."
 
No edit summary
 
(2 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{TUFLOW_Message
{{TUFLOW_Message
|tuflow_message=ERROR 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes.
|tuflow_message=ERROR 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes.
|alt_msg=WARNING 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes.
|alt_msg=NA
|type=[[ERROR]]
|type=[[ERROR]],[[WARNING]]
|message_desc=From 2017 onwards the SXL option is no longer supported for Nodes (Type = Node or blank). SXL is only available for Pit objects (Type = C, Q, R, W).
|message_desc=From 2017 onwards the SXL option is no longer supported for Nodes (Type = Node or blank). SXL is only available for Pit objects (Type = C, Q, R, W).
|suggestions=If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank.
|suggestions=If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank.

|discussion_page=* [[Talk:TUFLOW Message 1214|Discuss Message 1214]]

|link3=''
|link4=''
|prelink=[[TUFLOW_Message_1213|Message 1213]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1218|Message 1218]]
}}
}}

Latest revision as of 15:52, 22 December 2022

TUFLOW Message
ERROR 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes.

Alternate Message
WARNING 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes.

Message Type
ERROR,WARNING

Description
From 2017 onwards the SXL option is no longer supported for Nodes (Type = Node or blank). SXL is only available for Pit objects (Type = C, Q, R, W).

Suggestions
If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank.


Up
1xxx Messages