TUFLOW Message 1214: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
Created page with "{{TUFLOW_Message |tuflow_message=ERROR 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes. |alt_msg=NA |type=ERROR |message_desc=From 2017 onwards t..." |
No edit summary |
||
| (2 intermediate revisions by 2 users not shown) | |||
| Line 1: | Line 1: | ||
{{TUFLOW_Message |
{{TUFLOW_Message |
||
|tuflow_message=ERROR 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes. |
|tuflow_message=ERROR 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes. |
||
|alt_msg=WARNING 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes. |
|||
|alt_msg=NA |
|||
|type=[[ERROR]] |
|type=[[ERROR]],[[WARNING]] |
||
|message_desc=From 2017 onwards the SXL option is no longer supported for Nodes (Type = Node or blank). SXL is only available for Pit objects (Type = C, Q, R, W). |
|message_desc=From 2017 onwards the SXL option is no longer supported for Nodes (Type = Node or blank). SXL is only available for Pit objects (Type = C, Q, R, W). |
||
|suggestions=If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank. |
|suggestions=If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank. |
||
|discussion_page=* [[Talk:TUFLOW Message 1214|Discuss Message 1214]] |
|||
|link3='' |
|||
|link4='' |
|||
|prelink=[[TUFLOW_Message_1213|Message 1213]] |
|||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
||
|nextlink=[[TUFLOW_Message_1218|Message 1218]] |
|||
}} |
}} |
||
Latest revision as of 15:52, 22 December 2022
TUFLOW Message
ERROR 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes.
Alternate Message
WARNING 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes.
Description
From 2017 onwards the SXL option is no longer supported for Nodes (Type = Node or blank). SXL is only available for Pit objects (Type = C, Q, R, W).
Suggestions
If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank.
| Up |
|---|