{{TUFLOW_Message |
{{TUFLOW_Message |
||
|tuflow_message= |
|tuflow_message=ERROR 2320 - FC commands not yet supported in HPC or GPU solver. |
||
|alt_msg=ERROR 2320 - |
|alt_msg=ERROR 2320 - Read TGF command not yet supported in HPC or GPU solver.<br> |
||
ERROR 2320 - Read TGA command not yet supported in HPC or GPU solver.<br> |
|||
ERROR 2320 - TUFLOW 2016-03 GPU Solver does not support 1D links.<br> |
|||
ERROR 2320 - GLO commands not yet supported in HPC or GPU solver.<br> |
|||
ERROR 2320 - "Bed Resistance Values == CHEZY" not supported in HPC solver.<br> |
|||
ERROR 2320 - "Bed Resistance Values == MANNING M" not supported in HPC solver.<br> |
|||
WARNING 2320 - HPC or GPU Solver ignoring Read GIS Objects/Receptors commands.<br> |
|||
|type=[[WARNING]]<br> |
|type=[[WARNING]]<br> |
||
[[ERROR]]<br> |
[[ERROR]]<br> |
||
|message_desc= Some TUFLOW Classic functionalities are not supported by the TUFLOW HPC solver. |
|||
|message_desc= The attributes within the GIS layer referenced using the tgc command <font color="blue"><tt>Read GIS Code</tt></font> do not conform with the expected format of a 2d_code layer. |
|||
|suggestions= Active and inactive areas may be defined using the tgc commands <font color="blue"><tt>Read GIS Code</tt></font> and/or <font color="blue"><tt>Read GIS Code BC</tt></font>. When using the <font color="blue"><tt>Read GIS Code</tt></font> command, code values are extracted from objects in a 2d_code layer. When using the <font color="blue"><tt>Read GIS Code BC</tt></font>, code values are extracted from objects in a 2d_bc layer that have a Type attribute of “CD” and a code value taken from the 2d_bc f attribute. Confusing the GIS layer types with the two commands will result in a WARNING (or ERROR) 2320 message being produced. Check the GIS layer format is referenced using the correct tgc command. |
|||
|suggestions= |
|||
|discussion_page=* [[Talk:TUFLOW Message 2320|Discuss Message 2320]] |
|||
|link3='' |
|||
* If using a 2d_fc layer, change to a 2d_lfcsh layer which is supported by TUFLOW HPC. |
|||
|link4='' |
|||
* The 2016-03 TUFLOW GPU solver is a legacy feature, TUFLOW HPC (on GPU hardware) should be used instead. |
|||
|prelink=[[TUFLOW_Message_2319|Message 2319]] |
|||
* GLO commands are supported in TUFLOW HPC from the 2023-03-AD build and onwards. |
|||
* Read GIS Objects/Receptors commands are supported in TUFLOW HPC from the 2023-03-AA build and onwards. |
|||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] |
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] |
||
|nextlink=[[TUFLOW_Message_2321|Message 2321]] |
|||
}} |
}} |
||
Latest revision as of 16:03, 26 May 2025
TUFLOW Message
ERROR 2320 - FC commands not yet supported in HPC or GPU solver.
Alternate Message
ERROR 2320 - Read TGF command not yet supported in HPC or GPU solver.
ERROR 2320 - Read TGA command not yet supported in HPC or GPU solver.
ERROR 2320 - TUFLOW 2016-03 GPU Solver does not support 1D links.
ERROR 2320 - GLO commands not yet supported in HPC or GPU solver.
ERROR 2320 - "Bed Resistance Values == CHEZY" not supported in HPC solver.
ERROR 2320 - "Bed Resistance Values == MANNING M" not supported in HPC solver.
WARNING 2320 - HPC or GPU Solver ignoring Read GIS Objects/Receptors commands.
Description
Some TUFLOW Classic functionalities are not supported by the TUFLOW HPC solver.
Suggestions
- If using a 2d_fc layer, change to a 2d_lfcsh layer which is supported by TUFLOW HPC.
- The 2016-03 TUFLOW GPU solver is a legacy feature, TUFLOW HPC (on GPU hardware) should be used instead.
- GLO commands are supported in TUFLOW HPC from the 2023-03-AD build and onwards.
- Read GIS Objects/Receptors commands are supported in TUFLOW HPC from the 2023-03-AA build and onwards.
| Up |
|---|