|message_desc=From 2017 onwards the SXL option is no longer supported for Nodes (Type = Node or blank). SXL is only available for Pit objects (Type = C, Q, R, W).
|suggestions=If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank.
 
|discussion_page=* [[Talk:TUFLOW Message 1214|Discuss Message 1214]]
 