Difference between revisions of "TUFLOW Message 1214"

From Tuflow
Jump to navigation Jump to search
 
(One intermediate revision by the same user not shown)
Line 5: Line 5:
 
|message_desc=From 2017 onwards the SXL option is no longer supported for Nodes (Type = Node or blank). SXL is only available for Pit objects (Type = C, Q, R, W).
 
|message_desc=From 2017 onwards the SXL option is no longer supported for Nodes (Type = Node or blank). SXL is only available for Pit objects (Type = C, Q, R, W).
 
|suggestions=If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank.
 
|suggestions=If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank.
|discussion_page=* [[Talk:TUFLOW Message 1214|Discuss Message 1214]]
+
 
|link3=''
+
 
|link4=''
 
|prelink=[[TUFLOW_Message_1213|Message 1213]]
 
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1218|Message 1218]]
 
 
}}
 
}}

Latest revision as of 15:52, 22 December 2022

TUFLOW Message
ERROR 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes.

Alternate Message
WARNING 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes.

Message Type
ERROR,WARNING

Description
From 2017 onwards the SXL option is no longer supported for Nodes (Type = Node or blank). SXL is only available for Pit objects (Type = C, Q, R, W).

Suggestions
If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank.


Up
Go-up.png 1xxx Messages