TUFLOW Message 0935: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
 
(9 intermediate revisions by 4 users not shown)
Line 3: Line 3:
|alt_msg=NA
|alt_msg=NA
|type=[[CHECK]]
|type=[[CHECK]]
|message_desc=Access to the licence has been lost.
|message_desc=Access to the licence has been lost.<br>

|suggestions=Try plugging the licence dongle into a different USB port and/or on the different machine. Update your CodeMeter RunTime Kit, installation <u>[[http://www.codemeter.de/us/service/downloads.html|here]]</u>.<br>
As a background to the licencing, TUFLOW checks for a licence on model initialisation, and then periodically checks at a certain time interval, as well as at the end of the simulation. The CodeMeter licencing system used by TUFLOW will release any licences that are not in use after a period of time. This prevents the licence from being tied up forever by a force closed simulation (either closed through task manager or by clicking the red x at the top of the window). <br>
<br>
This message indicates either TUFLOW could not find any licence during a periodic check, or the licence has been already released between two periodic checks.
Prior to built 2018-03-AA the licence could get lost when the map output was very infrequent. The infrequent output could cause TUFLOW to drop the licence and attempt to re-take the licence after a long period. As a workaround, the map output frequency can be changed to more frequent or a small output zone can be set with more frequent output to invoke more frequent licence checks.<br>
|suggestions=''Fix connectivity issues:''<br>
<br>
*TUFLOW may lose licences during a network failure or a licence server shutdown. Please make sure a modelling machine has stable network access to the licence server.
Rarely, the licence could get lost for the 2018 TUFLOW releases when the map output was infrequent and the model didn't have any 1D or hidden 1D structures e.g. a QT boundary. As a workaround, the map output frequency can be changed to more frequent, a small output zone can be set with more frequent output or a dummy 1D channel can be created to invoke more frequent licence checks.<br>
*Some USB ports can lose power during a sleep mode and this can disconnect the licence dongle. Try plugging the licence dongle into a different USB port (preferably one of the USB ports on the back of the computer) as these should be much less likely to lose power / connectivity.
<br>
*Update your CodeMeter RunTime Kit, download available here: <u>https://www.wibu.com/support/user/user-software.html</u>.<br>
Please contact support@tuflow.com if the issue persist.

|discussion_page=* [[Talk:TUFLOW Message 0935|Discuss Message 0935]]
''Infrequent licence checks:''<br>
|link3=''
If you have checked all the connectivity issues and the problem still persists, this could be caused by licence being checked too infrequently. Prior to built 2018-03-AA the licence could get lost for HPC/GPU runs when the map output was very infrequent. This could cause TUFLOW to drop the licence and attempt to re-take the licence after a long period. A bug fix has been introduced for this in the 2018-03-AA build and later. But rarely, the licence can still get lost if the map output is infrequent, plus the model does not have ANY 1D or hidden 1D structures (e.g. a QT boundary). As a workaround:
|link4=''
* Include more frequent map output, possibly within an small dummy output zone to avoid large outputs.
|prelink=[[TUFLOW_Message_0933|Message 0933]]
* Include a dummy 1D channel to invoke the more frequent licence checks.



|uplink=[[0xxx_TUFLOW_Messages|0xxx Messages]]
|uplink=[[0xxx_TUFLOW_Messages|0xxx Messages]]
|nextlink=[[TUFLOW_Message_0938|Message 0938]]
}}
}}

Latest revision as of 14:45, 18 July 2024

TUFLOW Message
CHECK 0935 - Licence lost. Count = ",a,". Pausing for ",a," seconds.

Alternate Message
NA

Message Type
CHECK

Description
Access to the licence has been lost.

As a background to the licencing, TUFLOW checks for a licence on model initialisation, and then periodically checks at a certain time interval, as well as at the end of the simulation. The CodeMeter licencing system used by TUFLOW will release any licences that are not in use after a period of time. This prevents the licence from being tied up forever by a force closed simulation (either closed through task manager or by clicking the red x at the top of the window).
This message indicates either TUFLOW could not find any licence during a periodic check, or the licence has been already released between two periodic checks.

Suggestions
Fix connectivity issues:

  • TUFLOW may lose licences during a network failure or a licence server shutdown. Please make sure a modelling machine has stable network access to the licence server.
  • Some USB ports can lose power during a sleep mode and this can disconnect the licence dongle. Try plugging the licence dongle into a different USB port (preferably one of the USB ports on the back of the computer) as these should be much less likely to lose power / connectivity.
  • Update your CodeMeter RunTime Kit, download available here: https://www.wibu.com/support/user/user-software.html.

Infrequent licence checks:
If you have checked all the connectivity issues and the problem still persists, this could be caused by licence being checked too infrequently. Prior to built 2018-03-AA the licence could get lost for HPC/GPU runs when the map output was very infrequent. This could cause TUFLOW to drop the licence and attempt to re-take the licence after a long period. A bug fix has been introduced for this in the 2018-03-AA build and later. But rarely, the licence can still get lost if the map output is infrequent, plus the model does not have ANY 1D or hidden 1D structures (e.g. a QT boundary). As a workaround:

  • Include more frequent map output, possibly within an small dummy output zone to avoid large outputs.
  • Include a dummy 1D channel to invoke the more frequent licence checks.


Up