|tuflow_message=ERROR 0115 - First column values not in ascending order. Incorrect values are:
|alt_msg=ERROR 0115 - Time data not in ascending order
|type=[[ERROR]]
|message_desc=Data in first column, should be unique and in ascending order. For
|suggestions=Check data, remove duplicate values and sort by first column.<br>
This error can occur when using rainfall control file (.trfc) and having more than 1000 hyetograph entries in the BC database. As 1000 entries is a default limit, TUFLOW will read the correct vallue in the "Time" column in the row 1000, but it will read 0 in the row 1001 ignoring the original value. Command <font color="blue"><tt> Maximum Hyetograph Points </tt></font> <font color="red"><tt>== </tt></font> <tt><max_pts></tt> can be used to increase the default limit.
<br>
|uplink=[[0xxx_TUFLOW_Messages|0xxx Messages]]
}}
| |||