{{TUFLOW_Message
|tuflow_message=ERROR 20612060 - CouldUnrecognisable not find.tbc acommand CNor connectionproblem snappedreading toBC thedata endin offixed HXfield lineformat.<br>
Incorrect Line = "xxxxxx"
|alt_msg=NA
|type=[[ERROR]]
|message_desc=.tbc command is invalid or BC input file (e.g. bd_dbase.csv, HT/QT table, and etc) isn't in the correct data format.
|message_desc=Could not find a connection (CN object) snapped to the end of the 1D/2D interface (HX) line. Check that any connection object is snapped; add a connection to the end of the 1D/2D interface; or edit the 1D/2D interface line. 1D/2D interface lines based on the HX type must have as a minimum a connection at each of its ends, otherwise it is not clear how to transfer the water level gradient from the 1D domain.
|suggestions=Check which line in the input file is causing the issue from the error message, and ensure that .tbc command has no misspelling, or the input data is in the correct format.
|suggestions=Ensure that there is a CN object at each end of HX line connecting HX line to 1D node. The messages.mif or messages_P.shp file should contain the location that this error is occurring. Zoom into the HX line and check that the connection line is snapped to the end vertices of the line. This line can have CN connections snapped to intermediate vertices, but <u>'''must '''</u> have a CN line snapped to each end.
|discussion_page=* [[Talk:TUFLOW Message 2061|Discuss Message 2061]]
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_2059|Message 2059]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2061|Message 2061]]
}}
|