Difference between revisions of "TUFLOW Message 2060"

From Tuflow
Jump to navigation Jump to search
 
(5 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
|tuflow_message=ERROR 2060 - Unrecognisable .tbc command or problem reading BC data in fixed field format. Incorrect Line = "xxxxxx"
+
|tuflow_message=ERROR 2060 - Unrecognisable .tbc command or problem reading BC data in fixed field format.<br>
 +
Incorrect Line = "xxxxxx"
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=Could not find a connection (CN object) snapped to the end of the 1D/2D interface (HX) line. Check that any connection object is snapped; add a connection to the end of the 1D/2D interface; or edit the 1D/2D interface line. 1D/2D interface lines based on the HX type must have as a minimum a connection at each of its ends, otherwise it is not clear how to transfer the water level gradient from the 1D domain.
+
|message_desc=.tbc command is invalid or BC input file (e.g. bd_dbase.csv, HT/QT table, and etc) isn't in the correct data format.
|suggestions=Ensure that there is a CN object at each end of HX line connecting HX line to 1D node.  The messages.mif or messages_P.shp file should contain the location that this error is occurring.  Zoom into the HX line and check that the connection line is snapped to the end vertices of the line.  This line can have CN connections snapped to intermediate vertices, but <u>'''must '''</u> have a CN line snapped to each end.
+
|suggestions=Check which line in the input file is causing the issue from the error message, and ensure that .tbc command has no misspelling, or the input data is in the correct format.
|discussion_page=* [[Talk:TUFLOW Message 2061|Discuss Message 2061]]
+
 
|link3=''
+
 
|link4=''
 
|prelink=[[TUFLOW_Message_2059|Message 2059]]
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2061|Message 2061]]
 
 
}}
 
}}

Latest revision as of 11:50, 23 December 2022

TUFLOW Message
ERROR 2060 - Unrecognisable .tbc command or problem reading BC data in fixed field format.
Incorrect Line = "xxxxxx"

Alternate Message
NA

Message Type
ERROR

Description
.tbc command is invalid or BC input file (e.g. bd_dbase.csv, HT/QT table, and etc) isn't in the correct data format.

Suggestions
Check which line in the input file is causing the issue from the error message, and ensure that .tbc command has no misspelling, or the input data is in the correct format.


Up
Go-up.png 2xxx Messages