− | |type=[[ | + | |type=[[ERROR]] |
− | |message_desc= | + | |message_desc= No 1D node was found connected to variable Z shape 1D trigger. |
− | |suggestions= | + | |suggestions= Check that the trigger location is specified in the Trigger_1 (and/or Trigger_2) attribute, and the trigger point is snapped to a 1D node or a channel end. Note that this functionality is currently only available in TUFLOW 1D ESTRY engine. |
− | + | ||
− | |||
− | |||
− | |||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 14:24, 7 February 2023
TUFLOW Message
ERROR 2304 - Could not find 1D Node at Variable Z Trigger for Variable Z Shape.
Alternate Message
NA
Message Type
ERROR
Description
No 1D node was found connected to variable Z shape 1D trigger.
Suggestions
Check that the trigger location is specified in the Trigger_1 (and/or Trigger_2) attribute, and the trigger point is snapped to a 1D node or a channel end. Note that this functionality is currently only available in TUFLOW 1D ESTRY engine.