Created page with "{{TUFLOW_Message |tuflow_message=ERROR 2304 - Could not find 1D Node at Variable Z Trigger for Variable Z Shape. |alt_msg=NA |type=WARNING |message_desc= ???? |suggestions..." |
No edit summary |
||
| (5 intermediate revisions by 3 users not shown) | |||
Line 2:
|tuflow_message=ERROR 2304 - Could not find 1D Node at Variable Z Trigger for Variable Z Shape.
|alt_msg=NA
|type=[[
|message_desc= No 1D node was found connected to variable Z shape 1D trigger.
|suggestions= Check that the trigger location is specified in the Trigger_1 (and/or Trigger_2) attribute, and the trigger point is snapped to a 1D node or a channel end. Note that this functionality is currently only available in TUFLOW 1D ESTRY engine.
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
}}
| |||