Difference between revisions of "TUFLOW Message 2304"

From Tuflow
Jump to navigation Jump to search
(Created page with "{{TUFLOW_Message |tuflow_message=ERROR 2304 - Could not find 1D Node at Variable Z Trigger for Variable Z Shape. |alt_msg=NA |type=WARNING |message_desc= ???? |suggestions...")
 
 
(5 intermediate revisions by 3 users not shown)
Line 2: Line 2:
 
|tuflow_message=ERROR 2304 - Could not find 1D Node at Variable Z Trigger for Variable Z Shape.
 
|tuflow_message=ERROR 2304 - Could not find 1D Node at Variable Z Trigger for Variable Z Shape.
 
|alt_msg=NA
 
|alt_msg=NA
|type=[[WARNING]]
+
|type=[[ERROR]]
|message_desc= ????
+
|message_desc= No 1D node was found connected to variable Z shape 1D trigger.
|suggestions=????
+
|suggestions= Check that the trigger location is specified in the Trigger_1 (and/or Trigger_2) attribute, and the trigger point is snapped to a 1D node or a channel end. Note that this functionality is currently only available in TUFLOW 1D ESTRY engine.
|discussion_page=* [[Talk:TUFLOW Message 2304|Discuss Message 2304]]
+
 
|link3=''
 
|link4=''
 
|prelink=[[TUFLOW_Message_2302|Message 2302]]
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2305|Message 2305]]
 
 
}}
 
}}

Latest revision as of 14:24, 7 February 2023

TUFLOW Message
ERROR 2304 - Could not find 1D Node at Variable Z Trigger for Variable Z Shape.

Alternate Message
NA

Message Type
ERROR

Description
No 1D node was found connected to variable Z shape 1D trigger.

Suggestions
Check that the trigger location is specified in the Trigger_1 (and/or Trigger_2) attribute, and the trigger point is snapped to a 1D node or a channel end. Note that this functionality is currently only available in TUFLOW 1D ESTRY engine.


Up