TUFLOW Message 2441: Difference between revisions

Content deleted Content added
No edit summary
No edit summary
 
(2 intermediate revisions by 2 users not shown)
Line 3:
|alt_msg=ERROR 2441 - 2D VG boundaries not yet supported for HPC Solver.
|type=[[ERROR]]
|message_desc=The stage-discharge (HQ) boundaries are not available in earlier TUFLOW HPCGPU versions. The 2D VG boundaries not yet supported for HPC Solver.
|suggestions=Use the latest TUFLOW HPC release or the HQ boundary will need to be replaced with a HT boundary. If the water level is at ground level or below, normal flow is applied at the boundary. For functionality of 2D VG boundaries consider using TUFLOW Classic or variable Z shapes in TUFLOW HPC.
 
|discussion_page=* [[Talk:TUFLOW Message 2441|Discuss Message 2441]]
 
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_2440|Message 2440]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|nextlink=[[TUFLOW_Message_2442|Message 2442]]
}}