TUFLOW Message
WARNING 3525: Potentially SLOW SGS processing of grid using the double precision version of TUFLOW.
Alternate Message
N/A
Message Type
WARNING
Description
Due to an Intel Compiler issue this grid inspection has to be done with un-optimised code and will be slow. Note HPC solver does not generally require double precision engine. If XF files are enabled (default), subsequent initialisations will be much faster.
Suggestions
Consider whether double precision is needed in the project or allow for longer initialisation time.