(Created page with "{{TUFLOW_Message |tuflow_message=ERROR 1114 - P for Ogee Weir (WO) channel is invalid: 0. Check US_Invert and DS_Invert attributes. |alt_msg=NA |type=ERROR |message_desc=P...")
 
 
(2 intermediate revisions by 2 users not shown)
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=P for Ogee Weir (WO) channel is invalid: 0.
+
|message_desc=The height of the weir above its sill (P) for Ogee Weir (WO) channel is 0.
|suggestions=Check US_Invert and DS_Invert attributes.
+
|suggestions=For Ogee Weir (WO) channel, the absolute difference between the 1d_nwk attributes "US_Invert" and "DS_Invert" is used to set the height of the weir above its sill. Check these attribute and make sure P is correctly specified.
|discussion_page=* [[Talk:TUFLOW Message 1114|Discuss Message 1114]]
+
 
|link3=''
 
|link4=''
 
|prelink=[[TUFLOW_Message_1113|Message 1113]]
 
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1115|Message 1115]]
 
 
}}
 
}}

Latest revision as of 15:16, 22 December 2022

TUFLOW Message
ERROR 1114 - P for Ogee Weir (WO) channel is invalid: 0. Check US_Invert and DS_Invert attributes.

Alternate Message
NA

Message Type
ERROR

Description
The height of the weir above its sill (P) for Ogee Weir (WO) channel is 0.

Suggestions
For Ogee Weir (WO) channel, the absolute difference between the 1d_nwk attributes "US_Invert" and "DS_Invert" is used to set the height of the weir above its sill. Check these attribute and make sure P is correctly specified.


Up
Go-up.png 1xxx Messages