=Introduction=
Manholes are typically chambers used to provide one or all of the following; maintenance access, change in culvert direction, connections and change in culvert dimensions. By default, manholes are automatically created within TUFLOW at all conduit nodes, any manually created manhole will override the automatically created manhole.
Line 12 ⟶ 7:
*Change in height, width or diameter and/or invert level of the adjoining conduits.
<br>
The presence of a manhole at a junction point will override the exit loss of any conduit discharging into the manhole and entrance loss of any conduit takingcoming from ourout of the manhole. <br>
<br>
There are 3 types of manholes which can be specified in the 1d_mh_* layer:
Line 21 ⟶ 16:
 
=Manhole Losses=
When modelling conduit pipe flows, the head losses that the flow in pipe are subject to are made up of major losses (or friction losses) and minor losses (or local losses). Major losses are caused by forces between the flow and wetted perimeter of the conduit. Minor losses are caused by disruption to the flow due to bends, cross-sectional changes, fittings such as manholes and steps in the bed profile. Major losses are represented through the specification of a friction coefficient. The representation of minor losses, particularly for gravity networks, is at manholes and requires separate treatment. The default TUFLOW/Estry manhole loss approach uses the Engelund method explained in section 5.12.5.4 of the [https://wwwdownloads.tuflow.com/Download_archive/TUFLOW/Releases/2018-03/TUFLOW%20Manual.2018-03.pdf| TUFLOW user manual] although it is also possible to use a more simplified fixed manhole headloss approach too using the global <font color="blue"><tt>Manhole Default Loss Approach</tt></font> command or specifying within the '1d_mH_*' layer in the Loss_Approach attribute. The Engelund approach provides an automatic method for determining the loss coefficients as presented below. Of note is that the coefficients are recalculated every timestep, and therefore vary depending on the flow distribution between inlet and outlet conduits and the depth of water within the manhole. The losses represented are as follows:
<br>
<li>'''K<sub>entry</sub>''' covers the expansion of flow within the manhole at the outlet of an inlet conduit. The coefficient is applied as the exit loss of the inlet conduit.
Line 27 ⟶ 22:
<li>'''K<sub>drop</sub>''' is the loss coefficient due to a change in invert level and conduit height between inlet and outlet conduits.
<li>'''K<sub>Ɵ</sub>''' and '''K<sub>drop</sub>''' are added and applied as an energy loss for each outlet conduit.
<li>'''K<sub>exit</sub>''' covers the contraction from the manhole and re-expansion of flow within the entrance of an outlet conduit. It is applied as an entrance loss of the outlet.<br>
<li>'''K<sub>m</sub>''' is the user-defined manhole exit coefficient. <br>
<br>
The resulting headloss value is then applied, when sub-critical flow is experienced, to the standard head loss equation, i.e. dh = K*V<sup>2</sup>/2g. Where K is the loss coefficient, V is the conduit velocity and g the gravitational constant. The equations used for the Engelund loss approach are provided below:<br>
<br>
[[File:Engelund Equations.PNG|500px]]
Line 47 ⟶ 42:
'''W<sub>m</sub>''' = Flow width in manhole (1d_mh width attribute) <br>
'''y<sub>m</sub>''' = Depth of water in manhole <br>
'''A<sub>m</sub>''' = Flow arearea in manhole <br>
'''A'<sub>m</sub>''' = Effective flow arearea in manhole <br>
'''A<sub>p</sub>''' = Flow area of conduit <br>
'''K<sub>m</sub>''' = Manhole Loss Parameter (1d_mh Km attribute) <br>
Line 58 ⟶ 53:
<li>[[Manhole_Simple_Loss_Example#Example 1: Single Incoming/Outgoing Pipe with No Incoming Angle or Drop|Single Incoming/Outgoing Pipe with no angle and no drop]]
<li>[[Manhole_Simple_Loss_Example#Example 2: Single Incoming/Outgoing Conduit with Incoming Bend and Drop in Invert Levels|Single Incoming/Outgoing Pipe with incoming bend and drop in levels]]
<li>[[Manhole_Simple_Loss_Example#Example 3: Multiple Incoming Conduits with Incoming Bend and Drop in Invert Levels|Multiple Incoming Pipes with incoming bend and drop in levels]]<br>
 
<br>
In the case of the fixed headloss approach, the 1d_mh_* K_Fixed attribute is applied to the standard head loss equation, i.e. dh = K*V<sup>2</sup>/2g on the outlet conduit(s).<br>
 
<br>
 
Line 82 ⟶ 76:
[[File:Storage_chamber_csv.JPG|border|400px]]
<br>
For more information on storage nodes see Section 5.1011.34 ''Storage Nodes (User Defined NA Tables)'' within the [https://wwwdownloads.tuflow.com/Download/TUFLOW/Releases/2018-03Latest/TUFLOW%20Manual.2018-03.pdf| TUFLOW user manual]. If you have any further questions about manholes or any other aspect of TUFLOW functionality, please email TUFLOW support: [mailto:support@tuflow.com?Subject=TUFLOW%201D%20manholes%20help support@tuflow.com]
<br><br>
{{Tips Navigation
Back to [[TUFLOW_1D_Hydraulic_Structures | 1D Hydraulic Structures]]
|uplink=[[ TUFLOW 1D Channels and Hydraulic Structures | Back to 1D Channels and Hydraulic Structures]]
}}