{{TUFLOW_Message | {{TUFLOW_Message | ||
− | |tuflow_message=ERROR 1423 - Virtual Pit occurs at the same location as a user defined node, manhole or a pit IDs: <channel ids> | + | |tuflow_message=ERROR 1423 - Virtual Pit occurs at the same location as a user defined node, manhole or a pit IDs: <channel ids>. |
|alt_msg=N/A | |alt_msg=N/A | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
|message_desc=Virtual Pit outlet cannot be connected to the same location as a user defined node, manhole or a pit. | |message_desc=Virtual Pit outlet cannot be connected to the same location as a user defined node, manhole or a pit. | ||
− | |suggestions=Consider connection by upstream or downstream end of the channel instead. Virtual pits need to be read in before 1d_nwk if they are discharging into 1D channels. | + | |suggestions=Consider connection by upstream or downstream end of the channel instead. Virtual pits need to be read in before 1d_nwk if they are discharging into 1D channels.<br> |
− | + | ||
− | |||
− | |||
− | |||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 16:25, 5 January 2024
TUFLOW Message
ERROR 1423 - Virtual Pit occurs at the same location as a user defined node, manhole or a pit IDs: <channel ids>.
Alternate Message
N/A
Message Type
ERROR
Description
Virtual Pit outlet cannot be connected to the same location as a user defined node, manhole or a pit.
Suggestions
Consider connection by upstream or downstream end of the channel instead. Virtual pits need to be read in before 1d_nwk if they are discharging into 1D channels.