Difference between revisions of "TUFLOW Message 3531"

From Tuflow
Jump to navigation Jump to search
 
(3 intermediate revisions by 3 users not shown)
Line 5: Line 5:
 
|message_desc="SGS Approach == Method C" requires users to set SGS Sample Frequency in the '''.tcf''' file (not '''.tgc'''). The frequency sets the number of sample points across a cell face, with the square of the number being  
 
|message_desc="SGS Approach == Method C" requires users to set SGS Sample Frequency in the '''.tcf''' file (not '''.tgc'''). The frequency sets the number of sample points across a cell face, with the square of the number being  
 
the number of SGS sample locations per cell. It expects an odd number starting at 3 (9 cell sample locations).<br>
 
the number of SGS sample locations per cell. It expects an odd number starting at 3 (9 cell sample locations).<br>
For example, with <font color="blue"><tt>SGS Sample Frequency </tt></font> <font color="red"><tt>== </tt></font><tt>11</tt> and cell size of 10m, TUFLOW samples with'''1m''' interval at 11 points along a face including the two face vertexes at both ends.
+
For example, with <font color="blue"><tt>SGS Sample Frequency </tt></font> <font color="red"><tt>== </tt></font><tt>11</tt> and cell size of 10m, TUFLOW samples with '''1m''' interval at 11 points along a face including the two face vertexes at both ends.
 
For Quadtree models, different sample frequencies can be defined for each nesting level, e.g.:<br>
 
For Quadtree models, different sample frequencies can be defined for each nesting level, e.g.:<br>
 
<font color="blue"><tt>SGS Sample Frequency </tt></font> <font color="red"><tt>== </tt></font><tt>21, 11, 6</tt>
 
<font color="blue"><tt>SGS Sample Frequency </tt></font> <font color="red"><tt>== </tt></font><tt>21, 11, 6</tt>
 
|suggestions=Set SGS Sample Frequency in the .tcf file.
 
|suggestions=Set SGS Sample Frequency in the .tcf file.
|discussion_page=* [[Talk:TUFLOW Message 3531|Discuss Message 3531]]
+
 
|link3=''
 
|link4=''
 
|prelink=[[TUFLOW_Message_3530|Message 3530]]
 
 
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]]
 
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]]
|nextlink=[[TUFLOW_Message_3533|Message 3533]]
 
 
}}
 
}}

Latest revision as of 10:29, 3 March 2023

TUFLOW Message
ERROR 3531 - SGS Sample Frequency not set for SGS Approach == Method C.

Alternate Message
N/A

Message Type
ERROR

Description
"SGS Approach == Method C" requires users to set SGS Sample Frequency in the .tcf file (not .tgc). The frequency sets the number of sample points across a cell face, with the square of the number being the number of SGS sample locations per cell. It expects an odd number starting at 3 (9 cell sample locations).
For example, with SGS Sample Frequency == 11 and cell size of 10m, TUFLOW samples with 1m interval at 11 points along a face including the two face vertexes at both ends. For Quadtree models, different sample frequencies can be defined for each nesting level, e.g.:
SGS Sample Frequency == 21, 11, 6

Suggestions
Set SGS Sample Frequency in the .tcf file.


Up
Go-up.png 3xxx Messages