The '''<u>[[1D_Integrity_Tool_-_Pipe_Direction|Pipe Direction]]</u>''' integrity tool will check the pipe direction and will correct based on the selected options.
<ol>
<li> Ensure that '''1d_nwk_pipe_integrity_L_workshop_EG1_ID1_SN11d_nwk_MI01_Pipes_001_L_EG1_ID1_SN1''' layer is referenced in the 1D network Line Layers and select the '''Pipe Direction''' tab.
<li> Choose the '''‘Based on pipe direction continuity’''' option. This will perform a check based on the incoming and outgoing pipe directions. Run the tool.<br>