TUFLOW Message 1391: Difference between revisions
No edit summary |
No edit summary |
||
| (3 intermediate revisions by 2 users not shown) | |||
| Line 4: | Line 4: | ||
|type=[[ERROR]] |
|type=[[ERROR]] |
||
|message_desc=A TUFLOW 1D (ESTRY) node is trying to be connected to an external 1D scheme using a X1DH or X1DQ link as indicated in the message, but the TUFLOW node is already connected to an external 1D node using a link as indicated in the message. Only one external 1D scheme link can be specified for a TUFLOW (ESTRY) node. |
|message_desc=A TUFLOW 1D (ESTRY) node is trying to be connected to an external 1D scheme using a X1DH or X1DQ link as indicated in the message, but the TUFLOW node is already connected to an external 1D node using a link as indicated in the message. Only one external 1D scheme link can be specified for a TUFLOW (ESTRY) node. |
||
You can link two or more TUFLOW nodes to the same external 1D node by connecting the TUFLOW nodes (ie. snap them or use a connector (X) channel), and link to the external node. |
|||
|suggestions=Review connections to external 1D scheme for this node and remove the inappropriate one(s). |
|suggestions=Review connections to external 1D scheme for this node and remove the inappropriate one(s). |
||
|discussion_page=* [[Talk:TUFLOW Message 1391|Discuss Message 1391]] |
|||
|link3='' |
|||
|link4='' |
|||
|prelink=[[TUFLOW_Message_1382|Message 1382]] |
|||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
||
|nextlink=[[TUFLOW_Message_1991|Message 1991]] |
|||
}} |
}} |
||
Latest revision as of 10:39, 23 December 2022
TUFLOW Message
ERROR 1391 - Cannot connect Node with a X1DH or X1DQ link as the node is already connected to an external 1D domain via a X1DH or X1DQ link.
Alternate Message
NA
Message Type
ERROR
Description
A TUFLOW 1D (ESTRY) node is trying to be connected to an external 1D scheme using a X1DH or X1DQ link as indicated in the message, but the TUFLOW node is already connected to an external 1D node using a link as indicated in the message. Only one external 1D scheme link can be specified for a TUFLOW (ESTRY) node.
You can link two or more TUFLOW nodes to the same external 1D node by connecting the TUFLOW nodes (ie. snap them or use a connector (X) channel), and link to the external node.
Suggestions
Review connections to external 1D scheme for this node and remove the inappropriate one(s).