Difference between revisions of "TUFLOW Message 1394"

From Tuflow
Jump to navigation Jump to search
 
(One intermediate revision by the same user not shown)
Line 7: Line 7:
  
 
The other possibility is one of the attribute values is not correct (eg. if using a X1DQ link, this has been incorrectly entered).
 
The other possibility is one of the attribute values is not correct (eg. if using a X1DQ link, this has been incorrectly entered).
|discussion_page=* [[Talk:TUFLOW Message 1394|Discuss Message 1394]]
+
 
|link3=''
+
 
|link4=''
 
|prelink=[[TUFLOW_Message_1393|Message 1393]]
 
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1401|Message 1401]]
 
 
}}
 
}}

Latest revision as of 10:40, 23 December 2022

TUFLOW Message
ERROR 1394 - No external 1D scheme node linked or snapped to Node or invalid attribute value.

Alternate Message
NA

Message Type
ERROR

Description
A TUFLOW 1D (ESTRY) node could not be linked to an external 1D scheme node, or an attribute value is incorrect.

Suggestions
Check that the external 1D node is snapped to the TUFLOW node. Also make sure the external 1D nodes are being read in by TUFLOW using commands such as "Read GIS ISIS Network" or "Read GIS ISIS Nodes".

The other possibility is one of the attribute values is not correct (eg. if using a X1DQ link, this has been incorrectly entered).


Up
Go-up.png 1xxx Messages