Difference between revisions of "TUFLOW Message 2001"

From Tuflow
Jump to navigation Jump to search
 
(One intermediate revision by the same user not shown)
Line 10: Line 10:
 
<br>
 
<br>
  
|discussion_page=* [[Talk:TUFLOW Message 2001|Discuss Message 2001]]
+
 
|link3=''
 
|link4=''
 
|prelink=[[TUFLOW_Message_1991|Message 1991]]
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2002|Message 2002]]
 
 
}}
 
}}

Latest revision as of 10:51, 23 December 2022

TUFLOW Message
ERROR 2001 - 2d_bc object is outside 2D model domain

Alternate Message
ERROR 2001 - GIS Object is outside 2D model domain
WARNING 2001 - ",a," "object" at ",a,",",a," is outside 2D model domain

Message Type
ERROR
WARNING

Description
An object is located outside the 2D domain that it is assigned to. The Check Inside Grid == command controls whether this message is an ERROR, WARNING or not given.

Suggestions
The _messages_P.shp or _messages.mif layer in the log folder contains the locations of the offending boundary objects. Review the _dom_check file and the messages layer to ensure that all 2d_bc objects are within the model domain.
Check that the projection of the boundary layer is the same as the TUFLOW model projection.


Up