Difference between revisions of "TUFLOW Message 1041"

From Tuflow
Jump to navigation Jump to search
 
Line 8: Line 8:
 
Specify inverts upstream and downstream of the culvert, either via the US_invert / DS_invert in the 1D channel object or via snapped 1D node objects.  
 
Specify inverts upstream and downstream of the culvert, either via the US_invert / DS_invert in the 1D channel object or via snapped 1D node objects.  
  
|prelink=[[TUFLOW_Message_1037|Message 1037]]
 
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1042|Message 1042]]
 
 
}}
 
}}

Latest revision as of 13:52, 22 December 2022

TUFLOW Message
ERROR 1041 - Culvert branch splits downstream of channel ",a," at Node ",a,". Could not interpolate invert.

Alternate Message
ERROR 1041 - Culvert branch splits upstream of channel ",a," at Node ",a,". Could not interpolate invert.

Message Type
ERROR

Description
Multiple upstream or downstream channel, unable to interpolate inverts.

Suggestions
A useful tip at a junction of 1D channels is to use a connector (Channel_Type of “X”) for connecting a side tributary or pipe into the main flowpath. TUFLOW will then be able to interpolate inverts.

Specify inverts upstream and downstream of the culvert, either via the US_invert / DS_invert in the 1D channel object or via snapped 1D node objects.


Up
Go-up.png 1xxx Messages