|suggestions=Specify inverts upstream and downstream of the culvert, either via the US_invert / DS_invert in the 1D channel object or via snapped 1D node objects. | |suggestions=Specify inverts upstream and downstream of the culvert, either via the US_invert / DS_invert in the 1D channel object or via snapped 1D node objects. | ||
− | |||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 14:26, 22 December 2022
TUFLOW Message
ERROR 1042 - Could not find a culvert invert downstream of culvert ",a,". Downstream invert not interpolated.
Alternate Message
ERROR 1042 - Could not find a culvert invert upstream of culvert ",a,". Upstream invert not interpolated.
Message Type
ERROR
Description
No upstream / downstream invert specified, TUFLOW is unable to interpolate an invert.
Suggestions
Specify inverts upstream and downstream of the culvert, either via the US_invert / DS_invert in the 1D channel object or via snapped 1D node objects.