TUFLOW Message 1056: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
 
(One intermediate revision by one other user not shown)
Line 3: Line 3:
|alt_msg=ERROR 1056 - Incompatible flags "F" and "N" specified for CS data ",a," in ",a,
|alt_msg=ERROR 1056 - Incompatible flags "F" and "N" specified for CS data ",a," in ",a,
|type=[[ERROR]]
|type=[[ERROR]]
|message_desc='''"E"''' and '''"T"''' are flow area flags for XZ type cross-sections (see ecf command "Flow Area" in TUFLOW manual for more details). Specify an '''“E”''' to use effective area or a '''“T”''' to use total area when calculating the flow area. If neither is specified, the global value set using "<font color="blue"><tt>Flow Area </tt></font><font color="red"><tt>==</tt></font>" is used, the default flow area method is effective. <br>
|message_desc='''"E"''' and '''"T"''' are flow area flags for XZ type cross-sections (see ecf command "Flow Area" in <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for more details). Specify an '''“E”''' to use effective area or a '''“T”''' to use total area when calculating the flow area. If neither is specified, the global value set using "<font color="blue"><tt>Flow Area </tt></font><font color="red"><tt>==</tt></font>" is used, the default flow area method is effective. <br>
<br>
<br>
'''"F"''' and '''"N"''' are vertical change in resistance for CS or HW type cross-sections. Only '''''one''''' of the following should be specified:<br>
'''"F"''' and '''"N"''' are vertical change in resistance for CS or HW type cross-sections. Only '''''one''''' of the following should be specified:<br>
Line 10: Line 10:
|suggestions=Specify only '''''one''''' of either an "E" or a "T" for flow area flags or "F" or "N" for vertically varying resistance flags.
|suggestions=Specify only '''''one''''' of either an "E" or a "T" for flow area flags or "F" or "N" for vertically varying resistance flags.



|prelink=[[TUFLOW_Message_1055|Message 1055]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1057|Message 1057]]
}}
}}

Latest revision as of 09:55, 23 September 2024

TUFLOW Message
ERROR 1056 - Incompatible flags "E" and "T" specified for cross-section ",a," in ",a,

Alternate Message
ERROR 1056 - Incompatible flags "F" and "N" specified for CS data ",a," in ",a,

Message Type
ERROR

Description
"E" and "T" are flow area flags for XZ type cross-sections (see ecf command "Flow Area" in TUFLOW Manual for more details). Specify an “E” to use effective area or a “T” to use total area when calculating the flow area. If neither is specified, the global value set using "Flow Area ==" is used, the default flow area method is effective.

"F" and "N" are vertical change in resistance for CS or HW type cross-sections. Only one of the following should be specified:
“F” for a multiplication factor; or
“N” for a Manning’s n value.

Suggestions
Specify only one of either an "E" or a "T" for flow area flags or "F" or "N" for vertically varying resistance flags.


Up
1xxx Messages