TUFLOW Message 1070: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
 
(One intermediate revision by one other user not shown)
Line 3: Line 3:
|alt_msg=NA
|alt_msg=NA
|type=[[ERROR]]
|type=[[ERROR]]
|message_desc=If using effective area, a relative resistance factor of 1.0 must occur at some point in the profile to indicate the primary sub-channel. If this is not included, grossly incorrect channel velocities can occur.
|message_desc=????
|suggestions=Update the cross-sections to indicate a primary sub-channel:
|suggestions=????
* In the 1D cross-section table link (1d_xs) layer, ensure at least one cross-section has the "Flag" attribute set to "'''R'''".
* Update the corresponding source table to contain a relative resistance factor of 1.0.
Refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for more information on cross-sections.


|prelink=[[TUFLOW_Message_1069|Message 1069]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1071|Message 1071]]
}}
}}

Latest revision as of 16:14, 18 December 2024

TUFLOW Message
ERROR 1070 - Cross-section with effective area must have a relative resistance of 1 in primary sub-section.

Alternate Message
NA

Message Type
ERROR

Description
If using effective area, a relative resistance factor of 1.0 must occur at some point in the profile to indicate the primary sub-channel. If this is not included, grossly incorrect channel velocities can occur.

Suggestions
Update the cross-sections to indicate a primary sub-channel:

  • In the 1D cross-section table link (1d_xs) layer, ensure at least one cross-section has the "Flag" attribute set to "R".
  • Update the corresponding source table to contain a relative resistance factor of 1.0.

Refer to the TUFLOW Manual for more information on cross-sections.


Up
1xxx Messages