Difference between revisions of "TUFLOW Message 1095"
Line 20: | Line 20: | ||
Data<br> | Data<br> | ||
− | |||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
− | + | ||
}} | }} |
Latest revision as of 15:10, 22 December 2022
TUFLOW Message
XY: ERROR 1095 - Reading 1d_ta attribute data shown below: "","","","","","","", 0.000000000000000, 0.000000000000000,"xz". Check that the new format introduced in 2003-03-AA is used.
Alternate Message
ERROR 1095 - Reading 1d_ta attribute data from .mid file line below: Check that the new format introduced in 2003-03-AA is used. "","xz","","","","","","","", 0.000000000000000, 0.000000000000000
Message Type
ERROR
Description
The 1d_ta / 1d_xs does not have the correct attribute data.
Suggestions
Check the attributes by opening the .mif file in a text editor, columns 5:18 should look like the below:
Columns 12
Source Char(50)
Type Char(2)
Flags Char(8)
Column_1 Char(20)
Column_2 Char(20)
Column_3 Char(20)
Column_4 Char(20)
Column_5 Char(20)
Column_6 Char(20)
Z_Increment Float
Z_Maximum Float
Skew Float
Data
Up |
---|
1xxx Messages |