Difference between revisions of "TUFLOW Message 1100"
(4 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{TUFLOW_Message | {{TUFLOW_Message | ||
− | |tuflow_message=WARNING 1100 - Structure crest/invert is below bed of primary upstream channel | + | |tuflow_message=WARNING 1100 - Structure "a" crest/invert is below bed of primary upstream channel "b". |
− | |alt_msg= | + | |alt_msg= WARNING 1100 - Structure "a" crest/invert is below bed of primary downstream channel "b". |
|type=[[WARNING]] | |type=[[WARNING]] | ||
− | |message_desc=The WARNING is issued where a 1D structure’s invert/bed lies below the bed of the primary upstream and/or downstream channel. | + | |message_desc=The WARNING is issued where a 1D structure’s invert/bed lies below the invert/bed of the primary upstream and/or downstream channel. <br> |
− | |suggestions= For Build 2013-12-AB onwards, if this | + | The following diagrams provide a simplified elevation view of the two cases that trigger this warning: <br> <br> |
+ | '''''Structure "a" crest/invert is below bed of primary upstream channel'''''<br> | ||
+ | [[File:Invert below US channel.png]] <br><br> | ||
+ | '''''Structure "a" crest/invert is below bed of primary downstream channel'''''<br> <br> | ||
+ | [[File:Invert below DS channel.png]] <br> | ||
+ | <br> | ||
+ | |suggestions= For Build 2013-12-AB onwards, if this warning is issued, a review of the 1D topography and structure invert/dimensions is recommended. For Build 2013-12-AA, the issuing of this warning is incorrect and has no effect on the results. <br> | ||
+ | From Build 2023-03-AD onwards, this warning is eliminated when the connecting node is a manhole. Manholes often feature elevation drops between culverts making this warning unnecessary. | ||
− | |||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 15:30, 30 September 2024
TUFLOW Message
WARNING 1100 - Structure "a" crest/invert is below bed of primary upstream channel "b".
Alternate Message
WARNING 1100 - Structure "a" crest/invert is below bed of primary downstream channel "b".
Message Type
WARNING
Description
The WARNING is issued where a 1D structure’s invert/bed lies below the invert/bed of the primary upstream and/or downstream channel.
The following diagrams provide a simplified elevation view of the two cases that trigger this warning:
Structure "a" crest/invert is below bed of primary upstream channel
Structure "a" crest/invert is below bed of primary downstream channel
Suggestions
For Build 2013-12-AB onwards, if this warning is issued, a review of the 1D topography and structure invert/dimensions is recommended. For Build 2013-12-AA, the issuing of this warning is incorrect and has no effect on the results.
From Build 2023-03-AD onwards, this warning is eliminated when the connecting node is a manhole. Manholes often feature elevation drops between culverts making this warning unnecessary.
Up |
---|
1xxx Messages |