Latest revision as of 15:13, 22 December 2022
TUFLOW Message
ERROR 1105 - Width and/or height of R culvert is less than or equal to zero.
Alternate Message
NA
Message Type
ERROR
Description
Width and/or height of rectangular culvert (R type channel) is less than or equal to zero.
Suggestions
Enter a valid width into Width_or_Dia and a height into Height_or_WF GIS attributes. These are fields 14 and 15 in 1d_nwk layer, values in metres.