TUFLOW Message
ERROR 1114 - P for Ogee Weir (WO) channel is invalid: 0. Check US_Invert and DS_Invert attributes.

Alternate Message
NA

Message Type
ERROR

Description
The height of the weir above its sill (P) for Ogee Weir (WO) channel is 0.

Suggestions
For Ogee Weir (WO) channel, the absolute difference between the 1d_nwk attributes "US_Invert" and "DS_Invert" is used to set the height of the weir above its sill. Check these attribute and make sure P is correctly specified.