Line 5:
|alt_msg=NA
|type=[[WARNING]]
|message_desc=For a pump channel the depth valuesvs discharge curve represents the downstream head vs pump discharge curve. The first row should startspecify the discharge at zero (0) downstream head (i.e. start at zero depth), and the flowlast valuesrow should specify the maximum downstream head that the pump can work against (i.e. finish with zero flow).
|suggestions=Review the pump flow curve for the channel. The maximum head, difference between upstream and downstream invert, should have zero flow assigned.
 
|prelink=[[TUFLOW_Message_1124|Message 1124]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1126|Message 1126]]
}}