TUFLOW Message 3007: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
 
(One intermediate revision by one other user not shown)
Line 1: Line 1:
{{TUFLOW_Message
{{TUFLOW_Message
|tuflow_message=ERROR 3007: Wet/dry depth threshold must be >= 0.0001.
|tuflow_message=ERROR 3007 - Wet/dry depth threshold must be >= 0.0001.
<br>
|alt_msg=NA<br>
|alt_msg=none
|type=[[ERROR]]
|type=[[ERROR]]
|message_desc=The wet/dry depth threshold has been set to a value below the minimum allowed.
|message_desc=The wet/dry depth threshold has been set to a value below the minimum allowed.<br>
The default is 0.002m (2mm) or 0.007ft if using <font color="blue"><tt>Units </tt></font> <font color="red"><tt>== </tt></font> <tt>US Customary</tt>. The depth should be selected according
|suggestions=Ensure that the value specified with the "Cell Wet/Dry Depth" tcf command is a depth > 0.0001m.
to the magnitude of flooding depths. For broad-scale models with large cell sizes, values of up to 0.05m (0.16ft) have typically been used, while for models using the direct rainfall approach, or that have a high proportion of
steep flow, a wet/dry depth of less than 1mm (eg. 0.0002m or 0.0007ft) may be required due to the substantial amount of shallow sheet flow. A reduced wet/dry depth of 0.0002m (0.0007ft) is particularly recommended for direct
rainfall models.


|suggestions=Ensure that the value specified with the "<font color="blue"><tt>Cell Wet/Dry Depth</tt></font>" tcf command is a depth > 0.0001m.
The default is 0.002m (2mm) or 0.007ft if using Units == US Customary. The depth should be selected according to the magnitude of flooding depths. For broad-scale models with large cell sizes values of up to 0.05m (0.16ft) have typically been used, while for models using the direct rainfall approach, or that have a high proportion of steep flow, a wet/dry depth of less than a mm (eg. 0.0002m or 0.0007ft) may be required due to the substantial amount of shallow sheet flow. A reduced wet/dry depth of 0.0002m (0.0007ft) is particularly recommended for direct rainfall models.




|prelink=[[TUFLOW_Message_3006|Message 3006]]
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]]
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]]
|nextlink=[[TUFLOW_Message_3008|Message 3008]]
}}
}}

Latest revision as of 10:10, 3 March 2023

TUFLOW Message
ERROR 3007 - Wet/dry depth threshold must be >= 0.0001.

Alternate Message
NA

Message Type
ERROR

Description
The wet/dry depth threshold has been set to a value below the minimum allowed.
The default is 0.002m (2mm) or 0.007ft if using Units == US Customary. The depth should be selected according to the magnitude of flooding depths. For broad-scale models with large cell sizes, values of up to 0.05m (0.16ft) have typically been used, while for models using the direct rainfall approach, or that have a high proportion of steep flow, a wet/dry depth of less than 1mm (eg. 0.0002m or 0.0007ft) may be required due to the substantial amount of shallow sheet flow. A reduced wet/dry depth of 0.0002m (0.0007ft) is particularly recommended for direct rainfall models.

Suggestions
Ensure that the value specified with the "Cell Wet/Dry Depth" tcf command is a depth > 0.0001m.


Up