|tuflow_message=ERROR 3048: shearStressH1 must be > shearStressH0.
|tuflow_message=ERROR 3048 - Wind/Wave Shallow Depth 2 must be > Depth 1.
<br>
|alt_msg=NA<br>
|alt_msg=N/A


|type=[[ERROR]]
|type=[[ERROR]]
|message_desc=When applying wind/wave stresses the applied stress is blended between two threshold depths. Refer to the "<font color="blue"><tt>Wind/Wave Shallow Depths</tt></font>" command. The upper threshold depth is not greater than the lower threshold depth.
|message_desc=To be documented.
|suggestions=Review the values supplied to the "<font color="blue"><tt>Wind/Wave Shallow Depths</tt></font>" command.
|suggestions=Please contact <u>[mailto:support@tuflow.com support@tuflow.com]</u> for more information.


|discussion_page=* [[Talk:TUFLOW Message 3048|Discuss Message 3048]]
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_3047|Message 3047]]
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]]
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]]
|nextlink=[[TUFLOW_Message_3504|Message 3504]]
}}
}}

Latest revision as of 10:19, 3 March 2023

TUFLOW Message
ERROR 3048 - Wind/Wave Shallow Depth 2 must be > Depth 1.

Alternate Message
NA

Message Type
ERROR

Description
When applying wind/wave stresses the applied stress is blended between two threshold depths. Refer to the "Wind/Wave Shallow Depths" command. The upper threshold depth is not greater than the lower threshold depth.

Suggestions
Review the values supplied to the "Wind/Wave Shallow Depths" command.


Up
3xxx Messages