TUFLOW Message
ERROR 1343 - In ',A4,1X,a,' table above, Column 1 values not increasing. Values: ',a,' then

Alternate Message
NA

Message Type
ERROR

Description
The value in column 1 of the 1d_ta file does not increase as it progresses, as shown in the example below. This is usually the 'X' value for an XZ type table; or 'H' value for a HW type table.
Non-incremental HW Table.png

Suggestions
If there is a stepped increment in the 1d cross-section that you are trying to represent; it is possible to resolve this error by using a small increment of a millimetre between values in column 1 of the 1d_ta file.


Up
Go-up.png 1xxx Messages