Line 4:
|type=[[WARNING]]
|message_desc=A 1D pit object can be connected to a maximum of 10 2D cells.
|suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer. If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit.
 
If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. To use this approach, the 1d_nwk "Q" pit will need to be set up as a line rather than a point.
 