TUFLOW Message 2215: Difference between revisions
		
		
		
		Jump to navigation
		Jump to search
		
Content deleted Content added
| No edit summary | No edit summary | ||
| (One intermediate revision by one other user not shown) | |||
| Line 4: | Line 4: | ||
| |type=[[WARNING]] | |type=[[WARNING]] | ||
| |message_desc=A 1D pit object can be connected to a maximum of 10 2D cells. | |message_desc=A 1D pit object can be connected to a maximum of 10 2D cells. | ||
| |suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer.   | |suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer.   | ||
| If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. To use this approach, the 1d_nwk "Q" pit will need to be set up as a line rather than a point.  | |||
| |prelink=[[TUFLOW_Message_2214|Message 2214]] | |||
| |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
| |nextlink=[[TUFLOW_Message_2216|Message 2216]] | |||
| }} | }} | ||
Latest revision as of 20:36, 26 June 2024
TUFLOW Message 
WARNING 2215 - Exceeded limit of 2D cells connected to 1D pit object.
Alternate Message 
NA
Message Type 
WARNING
Description 
A 1D pit object can be connected to a maximum of 10 2D cells.
Suggestions 
Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer.  
If a very large pit object is modelled which requires connection to more 2D cell than the maximum a SX boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. To use this approach, the 1d_nwk "Q" pit will need to be set up as a line rather than a point.
| Up | 
|---|
|  2xxx Messages |