Difference between revisions of "TUFLOW Message 2222"

From Tuflow
Jump to navigation Jump to search
 
Line 7: Line 7:
 
|suggestions=Set a valid period in the GIS layer and/or check the very short period is intentional.
 
|suggestions=Set a valid period in the GIS layer and/or check the very short period is intentional.
  
|prelink=[[TUFLOW_Message_2221|Message 2221]]
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2223|Message 2223]]
 
 
}}
 
}}

Latest revision as of 14:13, 7 February 2023

TUFLOW Message
ERROR 2222 - Period attribute (eg. time taken for failure) must be greater than zero.

Alternate Message
WARNING 2222 - Period attribute (eg. time taken for failure) is very short.

Message Type
ERROR WARNING

Description
The period attribute in a variable z shape layer (2d_vzsh) defines the time in hours over which the variation in Zpt elevations occurs. This must be greater than zero. From 2020-01-AB warning is issued if Period attribute is greater than zero, but below 0.01hr. Previously Period under 0.001hr was recognised as zero and error was issued.

Suggestions
Set a valid period in the GIS layer and/or check the very short period is intentional.


Up
Go-up.png 2xxx Messages