Difference between revisions of "TUFLOW Message 2443"
(2 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{TUFLOW_Message | {{TUFLOW_Message | ||
− | |tuflow_message=ERROR 2443 - Exceeded limit of more than | + | |tuflow_message=ERROR 2443 - Exceeded limit of more than "<>" different source inflows on a single cell for HPC Solver. |
− | |alt_msg= | + | |alt_msg=ERROR 2443 - Exceeded limit of more than "<>" different source inflows on a single cell for GPU solver.<br> |
+ | ERROR 2443 - Sending HQ tracer to HPC Solver.<br> | ||
+ | ERROR 2443 - Sending RF tracers to HPC Solver.<br> | ||
+ | ERROR 2443 - Sending SA hydrograph to HPC Solver.<br> | ||
+ | ERROR 2443 - Sending SA tracers to HPC Solver.<br> | ||
+ | ERROR 2443 - Sending HT tracers to HPC Solver.<br> | ||
+ | ERROR 2443 - Sending SA hydrograph to Quadtree Solver.<br> | ||
+ | ERROR 2443 - Sending RF hydrograph time-series to Quadtree Solver.<br> | ||
+ | ERROR 2443 - Sending RF hydrograph cells to Quadtree Solver.<br> | ||
+ | ERROR 2443 - Sending SA hydrograph to GPU.<br> | ||
+ | |||
|type=[[ERROR]] | |type=[[ERROR]] | ||
|message_desc=Unlike TUFLOW Classic, the HPC solution scheme is limited to 4 different source inflows on a single cell. | |message_desc=Unlike TUFLOW Classic, the HPC solution scheme is limited to 4 different source inflows on a single cell. | ||
|suggestions=Review and adjust inflow sources in the model. | |suggestions=Review and adjust inflow sources in the model. | ||
− | + | ||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
− | + | ||
}} | }} |
Latest revision as of 15:21, 15 March 2024
TUFLOW Message
ERROR 2443 - Exceeded limit of more than "<>" different source inflows on a single cell for HPC Solver.
Alternate Message
ERROR 2443 - Exceeded limit of more than "<>" different source inflows on a single cell for GPU solver.
ERROR 2443 - Sending HQ tracer to HPC Solver.
ERROR 2443 - Sending RF tracers to HPC Solver.
ERROR 2443 - Sending SA hydrograph to HPC Solver.
ERROR 2443 - Sending SA tracers to HPC Solver.
ERROR 2443 - Sending HT tracers to HPC Solver.
ERROR 2443 - Sending SA hydrograph to Quadtree Solver.
ERROR 2443 - Sending RF hydrograph time-series to Quadtree Solver.
ERROR 2443 - Sending RF hydrograph cells to Quadtree Solver.
ERROR 2443 - Sending SA hydrograph to GPU.
Message Type
ERROR
Description
Unlike TUFLOW Classic, the HPC solution scheme is limited to 4 different source inflows on a single cell.
Suggestions
Review and adjust inflow sources in the model.
Up |
---|
2xxx Messages |