Difference between revisions of "TUFLOW Message 3033"

From Tuflow
Jump to navigation Jump to search
 
(One intermediate revision by one other user not shown)
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
|tuflow_message=ERROR 3033: Mannings n must be >= 0.
+
|tuflow_message=ERROR 3033 - Mannings n must be >= 0.
 
<br>  
 
<br>  
|alt_msg=None
+
|alt_msg=NA<br>
  
 
|type=[[ERROR]]  
 
|type=[[ERROR]]  
|message_desc=The specified Mannings n value must be greater than or equal to 0.0.  
+
|message_desc=When supplying gridded mannings n data, a 'u' or 'v' face uses a mannings n value that is negative.
|suggestions=Ensure the specified Mannings n value is greater than or equal to 0.0
+
|suggestions=Ensure the input gridded mannings data has no negative values.
  
|prelink=[[TUFLOW_Message_3032|Message 3032]]
 
 
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]]
 
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]]
|nextlink=[[TUFLOW_Message_3034|Message 3034]]
 
 
}}
 
}}

Latest revision as of 10:16, 3 March 2023

TUFLOW Message
ERROR 3033 - Mannings n must be >= 0.

Alternate Message
NA

Message Type
ERROR

Description
When supplying gridded mannings n data, a 'u' or 'v' face uses a mannings n value that is negative.

Suggestions
Ensure the input gridded mannings data has no negative values.


Up
Go-up.png 3xxx Messages