{{TUFLOW_Message
|tuflow_message=ERROR 3509 - Invalid SGS ZH SAMPLE RATIO. This value should be 0 ~ 1.
|alt_msg=NA<br>
 
|type=[[ERROR]]
|message_desc=Invalid SGS ZH Sample Ratio. This value is used to control the area used for SGS at ZH locations and it should be between 0 and 1. The area is set to <tt><''ratio''> X ''cell_area''</tt> to sample and generate Z values around a cell corner (the sampled elevations are not used in the hydraulic computations, only for map output).
|message_desc=
|suggestions=Ensure the .tgc command "<tt><font color="blue">SGS ZH Sample Ratio</font><font color="red"> ==</font></tt>" is set to a value between 0 and 1.
|suggestions=
 
|prelink=[[TUFLOW_Message_3508|Message 3508]]
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]]
|nextlink=[[TUFLOW_Message_3510|Message 3510]]
}}