Difference between revisions of "TUFLOW Message 2816"
(Created page with "{{TUFLOW_Message |tuflow_message=ERROR 2816 - |alt_msg=NA<br> |type=ERROR |message_desc= |suggestions= |prelink=Message 2815 |uplink=2xxx_TUFL...") |
|||
(6 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{TUFLOW_Message | {{TUFLOW_Message | ||
− | |tuflow_message=ERROR 2816 - | + | |tuflow_message=ERROR 2816 - Unable to read integer value from "<font color="blue"><tt>Set Code</tt></font>" line. |
− | |alt_msg= | + | |
+ | |alt_msg=ERROR 2816 - Unable to read code value from "<font color="blue"><tt>Read GIS Code BC </tt></font> <font color="red"><tt>==</tt></font>" polygon when processing Quadtree mesh.<br> | ||
+ | ERROR 2816 - Unable to read code value from "<font color="blue"><tt>Read GIS Code </tt></font> <font color="red"><tt>==</tt></font>" polygon when processing Quadtree mesh.<br> | ||
+ | ERROR 2816 - Unable to read IWL value after "<font color="blue"><tt>Set IWL </tt></font> <font color="red"><tt>==</tt></font>".<br> | ||
+ | ERROR 2816 - Unable to read IWL value.<br> | ||
+ | |||
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc= | + | |message_desc=TUFLOW is unable to read the input. |
− | |suggestions= | + | |suggestions=Check that the input is correct. For example "<font color="blue"><tt>Set IWL </tt></font> <font color="red"><tt>==</tt></font>" is expecting an integer value and ERROR 2816 may be produced if you are reading in an input later (e.g. 2d_iwl_R.shp) which instead should be read in using the "<font color="blue"><tt>Read GIS IWL</tt></font> <font color="red"><tt>==</tt></font>" command. <br> |
+ | Refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for more information. | ||
− | |||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 09:36, 23 September 2024
TUFLOW Message
ERROR 2816 - Unable to read integer value from "Set Code" line.
Alternate Message
ERROR 2816 - Unable to read code value from "Read GIS Code BC ==" polygon when processing Quadtree mesh.
ERROR 2816 - Unable to read code value from "Read GIS Code ==" polygon when processing Quadtree mesh.
ERROR 2816 - Unable to read IWL value after "Set IWL ==".
ERROR 2816 - Unable to read IWL value.
Message Type
ERROR
Description
TUFLOW is unable to read the input.
Suggestions
Check that the input is correct. For example "Set IWL ==" is expecting an integer value and ERROR 2816 may be produced if you are reading in an input later (e.g. 2d_iwl_R.shp) which instead should be read in using the "Read GIS IWL ==" command.
Refer to the TUFLOW Manual for more information.
Up |
---|
2xxx Messages |