Difference between revisions of "TUFLOW Message 2842"

From Tuflow
Jump to navigation Jump to search
(Created page with "{{TUFLOW_Message |tuflow_message=ERROR 2842 - |alt_msg=NA<br> |type=ERROR |message_desc= |suggestions= |prelink=Message 2841 |uplink=2xxx_TUFL...")
 
 
(2 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
|tuflow_message=ERROR 2842 -  
+
|tuflow_message=ERROR 2842 - QPC [Cell id=<>, x=<>, y=<>] has no active cell connected.
 
|alt_msg=NA<br>
 
|alt_msg=NA<br>
  
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=
+
|message_desc=A cell within Quadtree is isolated and has no active cell faces that connect to another cell.
|suggestions=
+
|suggestions=Check the message_P.shp layer to find the isolated cell and reconfigure the 2d_code and 2d_bc layers to stop the particular cell from being isolated (or remove it).
  
|prelink=[[TUFLOW_Message_2841|Message 2841]]
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2843|Message 2843]]
 
 
}}
 
}}

Latest revision as of 00:23, 28 May 2025

TUFLOW Message
ERROR 2842 - QPC [Cell id=<>, x=<>, y=<>] has no active cell connected.

Alternate Message
NA

Message Type
ERROR

Description
A cell within Quadtree is isolated and has no active cell faces that connect to another cell.

Suggestions
Check the message_P.shp layer to find the isolated cell and reconfigure the 2d_code and 2d_bc layers to stop the particular cell from being isolated (or remove it).


Up
Go-up.png 2xxx Messages