Difference between revisions of "TUFLOW Message 2415"

From Tuflow
Jump to navigation Jump to search
 
(4 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
|tuflow_message=ERROR 2415 - Too many regions for writing TIN files.  Please contact support@tuflow.com.
+
|tuflow_message=WARNING 2415 - Too many regions for writing TIN files.
|alt_msg=NA
+
|alt_msg=ERROR 2415 - Too many regions for writing TIN files.  Please contact support@tuflow.com.
|type=[[ERROR]]
+
|type=[[ERROR]] / [[WARNING]]  
|message_desc=????
+
|message_desc=Pre 2011-09, TUFLOW would stop with an ERROR 2415 if more than 10,000 regions to be TINned in a Read GIS Shape command when using XF files and/or specified within the WRITE TIN option. As of Build 2011-09-AE, TUFLOW continues without writing anymore XF files or TINs for the remaining regions and outputs a WARNING 2415.
|suggestions=????
+
|suggestions=None
|discussion_page=* [[Talk:TUFLOW Message 2415|Discuss Message 2415]]
+
 
|link3=''
 
|link4=''
 
|prelink=[[TUFLOW_Message_2414|Message 2414]]
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2418|Message 2416]]
 
 
}}
 
}}

Latest revision as of 10:34, 8 February 2023

TUFLOW Message
WARNING 2415 - Too many regions for writing TIN files.

Alternate Message
ERROR 2415 - Too many regions for writing TIN files. Please contact support@tuflow.com.

Message Type
ERROR / WARNING

Description
Pre 2011-09, TUFLOW would stop with an ERROR 2415 if more than 10,000 regions to be TINned in a Read GIS Shape command when using XF files and/or specified within the WRITE TIN option. As of Build 2011-09-AE, TUFLOW continues without writing anymore XF files or TINs for the remaining regions and outputs a WARNING 2415.

Suggestions
None


Up
Go-up.png 2xxx Messages