|tuflow_message=CHECK 2467 - Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZV point.
+
|tuflow_message=ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZV point.
|alt_msg=CHECK 2467 - Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZU point.<br>
+
|alt_msg=ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZU point.<br>
ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZU point.<br>
+
CHECK 2467 - Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZV point.<br>
ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZV point.
+
CHECK 2467 - Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZU point.
|type=[[CHECK]], [[ERROR]]
+
|type=[[ERROR]]<br>
 +
[[CHECK]]
 
|message_desc=A cell side encountered overlapping flow constrictions.
 
|message_desc=A cell side encountered overlapping flow constrictions.
|suggestions=Modify the flow constriction shapes to avoid overlapping. If the overlap is intentional, use a different flow constriction combining parameters from the original flow constrictions. From 2022 release, overlapping flow constriction triggers an error.
+
|suggestions=From 2023 release, overlapping flow constriction triggers an error.<br> Modify the flow constriction shapes to avoid overlapping. If the overlap is intentional, use a different flow constriction combining parameters from the original flow constrictions. Refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for more information.  
 +
 
 +
 
  
|prelink=[[TUFLOW_Message_2466|Message 2466]]
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2468|Message 2468]]
+
 
 
}}
 
}}

Latest revision as of 11:29, 7 October 2024

TUFLOW Message
ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZV point.

Alternate Message
ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZU point.
CHECK 2467 - Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZV point.
CHECK 2467 - Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZU point.

Message Type
ERROR
CHECK

Description
A cell side encountered overlapping flow constrictions.

Suggestions
From 2023 release, overlapping flow constriction triggers an error.
Modify the flow constriction shapes to avoid overlapping. If the overlap is intentional, use a different flow constriction combining parameters from the original flow constrictions. Refer to the TUFLOW Manual for more information.