TUFLOW Message
ERROR 1423 - Virtual Pit occurs at the same location as a user defined node, manhole or a pit IDs: <channel ids>.

Alternate Message
N/A

Message Type
ERROR

Description
Virtual Pit outlet cannot be connected to the same location as a user defined node, manhole or a pit.

Suggestions
Consider connection by upstream or downstream end of the channel instead. Virtual pits need to be read in before 1d_nwk if they are discharging into 1D channels.