|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc= | + | |message_desc=A cell within Quadtree is isolated and has no active cell faces that connect to another cell. |
− | |suggestions= | + | |suggestions=Check the message_P.shp layer to find the isolated cell and reconfigure the 2d_code and 2d_bc layers to stop the particular cell from being isolated (or remove it). |
− | |||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 00:23, 28 May 2025
TUFLOW Message
ERROR 2842 - QPC [Cell id=<>, x=<>, y=<>] has no active cell connected.
Alternate Message
NA
Message Type
ERROR
Description
A cell within Quadtree is isolated and has no active cell faces that connect to another cell.
Suggestions
Check the message_P.shp layer to find the isolated cell and reconfigure the 2d_code and 2d_bc layers to stop the particular cell from being isolated (or remove it).